
Tips for Cleaning and Servicing Explosion-Proof Submersible Pumps
Introduction
Explosion-proof submersible pumps are essential in hazardous environments where flammable gases, vapors, or dust may be present. These pumps are designed to operate safely in such conditions, but they require regular cleaning and servicing to maintain efficiency, safety, and longevity. Proper maintenance ensures compliance with safety standards and prevents costly breakdowns.
This guide provides detailed tips for cleaning and servicing explosion-proof submersible pumps, covering inspection, disassembly, cleaning, reassembly, and testing.
---
1. Safety Precautions Before Servicing
Before performing any maintenance on an explosion-proof submersible pump, follow these safety measures:
- Power Disconnection: Ensure the pump is completely disconnected from the power source to prevent accidental startup.
- Lockout/Tagout (LOTO): Use lockout/tagout procedures to secure the electrical supply.
- Hazardous Area Compliance: Verify that the environment is safe for maintenance. If flammable substances are present, follow ATEX, IECEx, or NEC guidelines.
- Personal Protective Equipment (PPE): Wear appropriate PPE, including gloves, safety goggles, and explosion-proof tools.
- Ventilation: Ensure proper ventilation if working in confined spaces to avoid gas buildup.
---
2. Inspection Procedures
A thorough inspection helps identify potential issues before they escalate.
Visual Inspection
- Check for physical damage such as cracks, dents, or corrosion on the pump casing, motor housing, and cables.
- Inspect cable integrity for cuts, abrasions, or exposed wires.
- Look for oil leaks (if the pump has an oil-filled motor).
- Examine seals and gaskets for wear or deterioration.
Electrical Inspection
- Test insulation resistance using a megohmmeter to ensure no electrical leakage.
- Check terminal connections for corrosion or loose wiring.
- Verify grounding continuity to prevent electrical hazards.
Performance Check
- Monitor flow rate and pressure to detect any drop in efficiency.
- Listen for unusual noises (grinding, rattling) that may indicate bearing or impeller damage.
- Check for overheating during operation, which could signal motor issues.
---
3. Disassembly of the Pump
Proper disassembly ensures components are not damaged during cleaning and servicing.
Step-by-Step Disassembly
1. Drain the Pump: Remove any remaining liquid from the pump casing.
2. Remove Fasteners: Use appropriate tools to loosen bolts and screws.
3. Separate Components: Carefully detach the motor from the pump body.
4. Extract the Impeller: Remove the impeller shaft, taking care not to damage the vanes.
5. Disassemble the Motor: If necessary, open the motor housing to inspect internal parts.
Handling Seals and Gaskets
- Avoid tearing O-rings and gaskets during removal.
- Replace damaged seals to prevent leaks upon reassembly.
---
4. Cleaning Procedures
Proper cleaning removes contaminants that could impair performance.
Cleaning the Pump Casing and Impeller
- Use a soft brush and mild detergent to scrub away debris, sludge, or scale buildup.
- For stubborn deposits, soak parts in a descaling solution (vinegar or commercial descaler).
- Avoid abrasive tools that could scratch surfaces and lead to corrosion.
Cleaning the Motor and Electrical Components
- Wipe down the motor housing with a damp cloth (do not immerse in water).
- Clean terminal connections with electrical contact cleaner.
- Blow out dust from cooling fins using compressed air (low pressure).
Cleaning the Cable and Connectors
- Inspect for corrosion or oxidation on connectors.
- Clean with isopropyl alcohol and a soft brush.
- Ensure waterproof seals are intact before reassembly.
---
5. Lubrication and Seal Replacement
Proper lubrication reduces friction and wear.
Bearing Lubrication
- Apply high-temperature grease to bearings as per manufacturer specifications.
- Avoid over-greasing, which can cause overheating.
Seal Replacement
- Replace mechanical seals if worn or damaged.
- Ensure proper alignment during installation to prevent leaks.
---
6. Reassembly and Alignment
Correct reassembly is critical for optimal performance.
Reassembly Steps
1. Reinstall the impeller and ensure it spins freely.
2. Secure the pump housing with evenly tightened bolts.
3. Reattach the motor, ensuring proper alignment with the pump shaft.
4. Replace all gaskets and O-rings to maintain watertight integrity.
Alignment Check
- Misalignment can cause vibration and premature wear.
- Use a dial indicator to verify shaft alignment if necessary.
---
7. Testing After Servicing
Before returning the pump to service, conduct thorough testing.
Dry Run Test (Without Liquid)
- Briefly power the pump to check for unusual noises or vibrations.
- Ensure the motor rotates smoothly.
Leak Test
- Submerge the pump in water and check for seal leaks.
- Monitor for oil leakage (if applicable).
Performance Test
- Run the pump under normal operating conditions.
- Measure flow rate, pressure, and power consumption to confirm efficiency.
Electrical Safety Test
- Recheck insulation resistance and grounding.
- Verify explosion-proof integrity (no exposed sparks or hot surfaces).
---
8. Preventive Maintenance Schedule
To extend pump life, follow a regular maintenance schedule:
- Daily: Check for unusual noises, leaks, or overheating.
- Weekly: Inspect cables and connections.
- Monthly: Test insulation resistance and clean intake filters.
- Annually: Full disassembly, cleaning, and seal replacement.
---
9. Common Issues and Troubleshooting
| Issue | Possible Cause | Solution |
|-----------|--------------------|--------------|
| Low Flow Rate | Clogged impeller or intake | Clean or replace impeller |
| Overheating | Blocked cooling fins or low oil level | Clean fins or refill oil |
| Excessive Vibration | Misalignment or worn bearings | Realign shaft or replace bearings |
| Electrical Fault | Damaged cable or poor insulation | Repair or replace wiring |
| Oil Leakage | Failed mechanical seal | Replace seal |
---
10. Storage Tips for Long-Term Inactivity
If the pump will not be used for an extended period:
- Drain all liquid to prevent freezing or corrosion.
- Store in a dry, clean environment away from direct sunlight.
- Rotate the shaft periodically to prevent bearing seizure.
- Reapply protective grease on exposed metal parts.
---
Conclusion
Proper cleaning and servicing of explosion-proof submersible pumps are crucial for safety, efficiency, and durability. By following these guidelines—regular inspection, careful disassembly, thorough cleaning, correct reassembly, and testing—you can ensure reliable performance in hazardous environments. Implementing a preventive maintenance schedule will minimize downtime and extend the pump’s operational life. Always adhere to safety protocols and manufacturer recommendations to maintain explosion-proof integrity.


Phone:+86 15868545868/+8618968868555
whatsapp:+86 15868545868/+8618968868555
Email:haiwan@haiwanpump.cn
Add:Meiao Street, Qiaoxia Town, Yongjia County Wenzhou City, Zhejiang, China
Copyright ? 2025 Zhejiang Haiwan Pump Industry Co., Ltd.
Comment
(0)